High Power Opto Sensors PANTRON
Looking for the price?
ISM series base model; single channel system with manual operation. Electronic output stage (PhotoMOS). Test input for functional test by external test equipment. Available as screw terminal version or plug version.
Number of channels | 1 |
Range (using transmitter ITL combined with receiver IRL / IRH) |
7 m / 15 m (23 ft / 49 ft) |
Range (using transmitter ITH combined with receiver IRL / IRH) |
10 m / 25 m (33 ft / 82 ft) |
Range (using transmitter ITA combined with IRL / IRH) |
20 m / 55 m (66 ft /180 ft) |
Operating mode | manual |
Transmit frequency |
3,9 kHz |
Switching outputs |
60 V AC / DC short-circuit proof |
Response time |
24 ms |
Test input |
24 V DC |
Supply voltage |
24 V DC |
Version: Screw terminal |
Order code: ISM-1000S/24VDC |
Version: Plug connection |
Order code: ISM-1000/24VDC
|
|
Single channel system with manual operation. Two manual modes for individual range setting. Light/dark switchmode for inverted output signal. Four frequency settings allow close mounting of adjacent beams. LED indicators for output signal and gain control. Alarm indicator and alarm output. Electronic output stage (Photo-MOS). Test input for functional test by external test equipment.
Number of channels |
1 |
Range (using transmitter ITL combined with receiver IRL / IRH) |
7 m / 15 m |
Range (using transmitter ITH combined with receiver IRL / IRH) |
10 m / 25 m |
Range (using transmitter ITA combined with receiver IRL / IRH) |
20 m / 55 m |
Operating modes |
manual high/low |
Transmit frequencies |
3,5 / 3,8 / 4,0 / 4,5 kHz |
Switching outputs |
60 V AC / DC short-circuit proof |
Response time |
24 ms |
Alarm output |
PNP 24 V, 100 mA |
Test input |
24 V DC |
Supply voltage | 24 V DC |
Version: Screw terminal |
Order code: ISM-1100S/24VDC |
Version: Plug connection |
Order code: ISM-1100/24VDC |
|
Single channel system with manual and automatic operation. Two levels per each mode for individual range setting. Light/dark switchmode for inverted output signal. Two frequency settings allow close mounting of adjacent beams. Sensor alignment information and diagnostics are available at the touch of a button. The analog output makes sensor alignment easy and can also be used for simple measurement tasks. LED indicators for output signal and gain control.
Number of channels |
1 |
Range (using transmitter ITL combined with receiver IRL / IRH) |
7 m / 15 m (23 ft / 49 ft) |
Range (using transmitter ITH combined with receiver IRL / IRH) |
10 m / 25 m (33 ft / 82 ft) |
Range (using transmitter ITA combined with receiver IRL / IRH) |
20 m / 55 m (66 ft 180 ft) |
Operating modes | 2 manual / 2 automatic |
Transmit frequencies |
3,7 / 4,3 kHz |
Switching outputs |
60 V AC / DC short-circuit proof |
Response time |
24 ms |
Alarm output |
PNP 24 V, 100 mA |
Analog output |
0...10 V |
Test input |
24 V DC |
Supply voltage |
24 V DC |
Version: Screw terminal |
Order code: ISM-1200S/24VDC |
Version: Plug connection |
Order code: ISM-1200/24VDC |
|
AC powered model with relay output for stand-alone operation. Single channel system with manual and automatic operation. Two levels per each mode for individual range setting. Timer functions for on-delay, off-delay and pulse forming. Light/dark switchmode for inverted output signal. Two frequency settings allow close mounting of adjacent beams. Sensor alignment information and diagnostics are available at the touch of a button. The analog output makes sensor alignment easy and can also be used for simple measurement tasks.
Number of channels |
1 |
Range (using transmitter ITL combined with receiver IRL / IRH) |
8 m / 15 m (26 ft / 49 ft) |
Range (using transmitter ITH combined with receiver IRL / IRH) |
10 m / 20 m (33 ft / 66 ft) |
Range (using transmitter ITA combined with receiver IRL / IRH) |
20 m / 50 m (66 ft / 164 ft) |
Operating modes | 2 manual / 2 automatic |
Transmit frequencies |
3,7 / 4,3 kHz |
Switching output |
250 V AC / 5 A |
Switching frequency |
20 Hz |
Alarm output |
Normally open contact 60 V AC, 100 mA |
Error output |
Normally open contact 60 V AC, 100 mA |
Test input |
Activ low |
Supply voltage |
230 / 115 / 24 V AC |
Version: 230 V AC |
Order code: ISM-1220S/230VAC |
Version: 115 V AC |
Order code: ISM-1220S/115VAC |
Version: 24 V AC |
Order code: ISM-1220S/24VAC |
|
ISM-1500 series optosensors are cost-efficient devices for simple light barrier applications. In consequence of the standard size of 22,5 mm, the low profile and the plug-in connections these devices are easy to mount and space-saving. The amplifiers are used for detecting objects in machines or production facilities. The whole system consists of one amplifier combined with infrared transmitter and receiver. It is characterised by its long detection range and extreme dirt resistance where traditional photo-electric light barriers reach their limits.
Number of channels |
1 |
Range (using transmitter ITL combined with receiver IRL / IRH) |
20 m / 25 m (66 ft / 82 ft) |
Range (using transmitter ITH combined with receiver IRL / IRH) |
30 m / 35 m (98 ft / 115 ft) |
Range (using transmitter ITA combined with receiver IRL / IRH) |
50 m / 70 m (164 ft / 230 ft) |
Operating mode |
manual |
Transmit frequency |
4,0 kHz |
Switching outputs ISM-1510 |
Potential-free normally open contact (relay), 250 V AC / 24 V DC, 5 A |
Switching outputs ISM-1515 |
Potential-free normally open contact (semiconductor relay), short-circuit proof, 60 V AC / DC, 100 mA |
Response time |
36 ms |
Supply voltage |
24 V AC / DC |
Version with Relay |
Order code: ISM-1510/24V |
Version with Semiconductor relay |
Order code: ISM-1515/24V |
|
ISM-1500 series optosensors are cost-efficient devices for simple light barrier applications. The amplifiers are used for detecting objects in machines or production facilities. The whole system consists of one amplifier combined with infrared transmitter and receiver. It is characterised by its long detection range and extreme dirt resistance where traditional photo-electric light barriers reach their limits. Modulated light is the reason for additional safety regarding external light, interfering impulses and other light barriers.
Number of channels |
1 |
Range (using transmitter ITL combined with receiver IRL / IRH) |
20 m / 25 m (66 ft / 82 ft) |
Range (using transmitter ITH combined with receiver IRL / IRH) |
30 m / 35 m (98 ft / 115 ft) |
Range (using transmitter ITA combined with receiver IRL / IRH) |
50 m / 70 m (164 ft / 230 ft) |
Transmit frequency |
4,0 kHz |
Switching outputs |
Potential-free normally open contact (semiconductor relay), short-circuit proof, 60 V AC / DC, 100 mA |
Response time |
36 ms |
Supply voltage |
24 V AC / DC |
|
ISM-1500 series optosensors are cost-efficient devices for simple light barrier applications. In consequence of the standard size of 22,5 mm, the low profile and the plug-in connections these devices are easy to mount and space-saving. The amplifiers are used for detecting objects in machines or production facilities. The whole system consists of one amplifier combined with infrared transmitter and receiver. It is characterised by its long detection range and extreme dirt resistance where traditional photo-electric light barriers reach their limits.
Number of channels |
1 |
Range (using transmitter ITL with receiver IRL / IRH) |
20 m / 25 m (66 ft / 82 ft) |
Range (using transmitter ITH with receiver IRL / IRH) |
30 m / 35 m (98 ft / 115 ft) |
Range (using transmitter ITA with receiver IRL / IRH) |
50 m / 70 m (164 ft / 230 ft) |
Operating mode |
manual high/low |
Transmit frequency |
4,0 kHz |
Switching outputs ISM-1510 |
Potential-free normally open contact (relay), 250 V AC / 24 V DC, 5 A |
Switching outputs ISM-1515 |
Potential-free normally open contact (semiconductor relay), short-circuit proof, 60 V AC / DC, 100 mA |
Response time |
36 ms |
Supply voltage |
24 V AC / DC |
Version with Relay |
Order code: ISM-1520/24V |
Version with Semiconductor relay |
Order code: ISM-1525/24V |
|
ISM-1500 series optosensors are cost-efficient devices for simple light barrier applications. In consequence of the standard size of 22,5 mm, the low profile and the plug-in connections these devices are easy to mount and space-saving. The amplifiers are used for detecting objects in machines or production facilities. The whole system consists of one amplifier combined with infrared transmitter and receiver. It is characterised by its long detection range and extreme dirt resistance where traditional photo-electric light barriers reach their limits.
Number of channels |
1 |
Range (using transmitter ITL combined with receiver IRL / IRH) |
20 m / 25 m (66 ft / 82 ft) |
Range (using transmitter ITH combined with receiver IRL / IRH) |
30 m / 35 m (98 ft / 115 ft) |
Range (using transmitter ITA combined with receiver IRL / IRH) |
50 m / 70 m (164 ft / 230 ft) |
Operating mode |
manual |
Transmit frequency |
4,0 kHz |
Switching outputs ISM-1510 |
Potential-free normally open contact (relay), 250 V AC / 24 V DC, 5 A |
Switching outputs ISM-1515 |
Potential-free normally open contact (semiconductor relay), short-circuit proof, 60 V AC / DC, 100 mA |
Response time |
36 ms |
Supply voltage |
24 V AC / DC |
Version with Relay |
Order code: ISM-1530/24V |
Version with Semiconductor relay |
Order code: ISM-1535/24V |
|
Two channel multiplexed system with manual and automatic operation. Two levels per each mode for individual range setting. Light/dark switchmode for inverted output signal. Sensor alignment information and diagnostics are available at the touch of a button. LED indicators for output signal and gain control. Alarm indicator and alarm output. Electronic output stage (PhotoMOS). Test input for functional test by external test equipment. Available as screw terminal version or plug version (see picture).
Number of channels |
1 |
Range (using transmitter ITL combined with receiver IRL / IRH) |
8 m / 20 m (26 ft / 66 ft) |
Range (using transmitter ITH combined with receiver IRL / IRH) |
10 m / 30 m (33 ft / 98 ft) |
Range (using transmitter ITA combined with receiver IRL / IRH) |
20 m / 55 m (66 ft / 180 ft) |
Transmit frequency |
4,0 kHz |
Switching outputs |
Potential-free normally open contact (semiconductor relay), short-circuit proof, 60 V AC / DC, 100 mA |
Response time |
36 ms |
Supply voltage |
24 V AC / DC |
|
Four channel multiplexed system with manual and automatic operation modes. Menu-driven setup allows individual parameter setting for each channel. Sensor error monitoring shows error messages on the LCD display during normal operation. Info screens for each channel indicate the current settings and performance. Multiple ISM units can be synchronized using the master slave function, up to 40 virtually independent beams. Computer interface for remote diagnostic and remote programming.
Number of channels |
4 |
Multiplex-speed |
18 ms |
Range (using transmitter ITL with receiver IRL / IRH) |
10 m / 15 m (33 ft / 49 ft) |
Range (using transmitter ITH with receiver IRL / IRH) |
12 m / 25 m (39 ft / 82 ft) |
Range (using transmitter ITA with receiver IRL / IRH) |
25 m / 60 m (82 ft / 197 ft) |
Operating modes |
2 manual / 4 automatic |
Transmit frequency |
4 kHz |
Switching outputs |
60 V AC / DC short-circuit proof |
Response time |
20 ms |
Alarm output |
PNP 24 V, 100 mA |
Error output |
PNP 24 V, 100 mA |
Analog output |
0...10 V |
Test input |
24 V DC |
Interface |
The RS232-Interface is exclusively suitable for the communication between the ISM-4000 and the software WinISM. |
Supply voltage |
24 V DC |
|
Eight channel multiplexed system with manual and automatic operation modes. Menu-driven setup allows individual parameter setting for each channel. Sensor error monitoring shows error messages on the LCD display during normal operation. Info screens for each channel indicate the current settings and performance. Detailed performance and error information are indicated in diagnostic mode, making troubleshooting easy. In curtain mode output signals are summarized on one single output. Multiple ISM units can be synchronized using the master slave function, up to 40 independent beams.
Number of channels |
8 |
Multiplex-speed |
34 ms |
Range (using transmitter ITL with receiver IRL / IRH) |
10 m / 15 m (33 ft / 49 ft) |
Range (using transmitter ITH with receiver IRL / IRH) |
12 m / 25 m (39 ft / 82 ft) |
Range (using transmitter ITA with receiver IRL / IRH) |
25 m / 60 m (82 ft / 197 ft) |
Operating modes |
2 manual / 4 automatic |
Transmit frequency |
4 kHz |
Switching outputs |
60 V AC / DC short-circuit proof |
Response time |
20 ms |
Alarm output |
PNP 24 V, 100 mA |
Error output |
PNP 24 V, 100 mA |
Analog output |
0...10 V |
Test input |
24 V DC |
Interface |
The RS232-Interface is exclusively suitable for the communication between the ISM-4000 and the software WinISM. |
Supply voltage |
24 V DC |
|
The ICL-2100 is a dual-channel opto sensor with two manual and four automatic operating modes. This device replaces two single-channel opto sensors with the advantage of no mutual interaction between each single channel. The device settings can be changed with the related software only. It is possible to program eight different basic settings which can be selected via DIP switch. The Master/Slave operation provides the possibility to synchronize two of the following amplifiers: ICL-2100, ICL-6100 and ICL-8100. That means that a system of two combined amplifiers works with 2, 4, 6, 8, 10, 12, 14 or even 16 totally independent channels.
Number of channels |
2 |
Multiplex-speed |
10 ms |
Range (using transmitter ITL with receiver IRH) |
12 m (39 ft) |
Range (using transmitter ITH with receiver IRH) |
19 m (62 ft) |
Range (using transmitter ITA with receiver IRH) |
35 m (115 ft) |
Operating modes |
2 manual / 4 automatic |
Transmit frequency |
4 kHz |
Switching outputs |
24 V DC, 100 mA short-circuit proof |
Response time |
12 ms |
Alarm output |
24 V DC, 100 mA short-circuit proof |
Analog output |
0...10 V |
Test input |
24 V DC |
Interface |
The RS232-Interface is exclusively suitable for the communication between the ICL-2100 and the software WinICL |
Supply voltage |
24 V DC ± 20% |
|
The ICL-6100 is a six-channel opto sensor with two manual and four automatic operating modes. This device replaces six single-channel opto sensors with the advantage of no mutual interaction between each single channel. The automatic operating mode provides a secure functionality that adjusts to external interferences, deterioration and misalignment of the sensors. The device has semiconductor outputs. The Master/Slave operation provides the possibility to synchronize two of the following amplifiers: ICL-2100, ICL-6100 and ICL-8100. That means that a system of two combined amplifiers works with 2, 4, 6, 8, 10, 12, 14 or even 16 totally independent channels.
Number of channels |
6 |
Multiplex-speed |
10 ms |
Range (using transmitter ITL with receiver IRH) |
15 m (59 ft) |
Range (using transmitter ITH with receiver IRH) |
20 m (66 ft) |
Range (using transmitter ITA with receiver IRH) |
35 m (115 ft) |
Operating modes |
2 manual / 4 automatic |
Transmit frequency |
4 kHz |
Switching outputs |
24 V DC, 100 mA short-circuit proof |
Response time |
12 ms |
Alarm output |
24 V DC, 100 mA short-circuit proof |
Analog output |
0...10 V |
Test input |
24 V DC |
Interface |
The RS232-Interface is exclusively suitable for the communication between the ICL-2100 and the software WinICL |
Supply voltage |
24 V DC ± 20% |
|
The ICL-8100 is a eight-channel opto sensor with two manual and four automatic operating modes. This device replaces eight single-channel opto sensors with the advantage of no mutual interaction between each single channel. The automatic operating mode provides a secure functionality that adjusts to external interferences, deterioration and misalignment of the sensors. The device has semiconductor outputs. The device has semiconductor outputs. The Master/Slave operation provides the possibility to synchronize two of the following amplifiers: ICL-2100, ICL-6100 and ICL-8100. That means that a system of two combined amplifiers works with 2, 4, 6, 8, 10, 12, 14 or even 16 totally independent channels.
Number of channels |
8 |
Multiplex-speed |
10 ms |
Range (using transmitter ITL with receiver IRH) |
15 m (59 ft) |
Range (using transmitter ITH with receiver IRH) |
20 m (66 ft) |
Range (using transmitter ITA with receiver IRH) |
35 m (115 ft) |
Operating modes |
2 manual / 4 automatic |
Transmit frequency |
4 kHz |
Switching outputs |
24 V DC, 100 mA short-circuit proof |
Response time |
12 ms |
Alarm output |
24 V DC, 100 mA short-circuit proof |
Analog output |
0...10 V |
Test input |
24 V DC |
Interface |
The RS232-Interface is exclusively suitable for the communication between the ICL-2100 and the software WinICL |
Supply voltage |
24 V DC ± 20% |
|